DEVI offers a large variety of underfloor heating systems
 
 
 
 
 
 
 
 
 
 
 
 
   
General Information Technical Information

Devireg™ 130 / 131 / 132

Technical Reference

Dimensions
71mm x 71mm (thermostat)
85mm x 85mm (patrise)
Voltage
240V ~
Maximum Load
16 Amps
Inductive Load
1 Amp
Switch
2 Pole
Hysteresis (degree of accuracy)
0.2°C
Control Light
LED diode
Mounting
Surface
Sensor Type
NTC 25°C/15 kOhm
Standard Sensor Length
4m
Economy Set Back
5°C
Moisture Proof
1P 30
Colour
Polar White
Wall Box
155 PM / PDL 1547
Product Code   
Sensor Method
Temperature Range: Air Sensor
Temperature Range: Floor Sensor
Devireg 130
19112015
Floor Probe
-
5°C to 45°C
Devireg 131
19112038
Built-in Air Sensor
5°C to 35°C
-
Devireg 132
19112062
Floor Probe & Built-in Air Sensor
5°C to 35°C
20°C to 60°C
PLEASE NOTE:
Floor Sensor Probes must be installed into a separate conduit that will always be accessible if removal of sensor is ever required. The sensor conduit with no more than one bend shall be installed from the floor to the thermostat or junction box located directly above the heated area.

Floor sensor cableFloor Sensor

Floor Sensor included with Thermostat. 
Sensor Cable can be extended up to 50m (using 2 x 1.5mm2)

Connection Diagrams:

Connection diagram for Devireg 130

Connection diagram for Devireg 131

Devireg™ 130

Devireg™ 131

Conncetion diagram for Devireg 132

Devireg™ 132

IMPORTANT:

To prevent damage to the thermostat a suitably sized contactor MUST be used for loads over 16 Amps. Contactor sizing and installation must be in accordance with the manufacturer's recommendations.

Electrical load diagam

PDF - Devireg™ 130 Installation & Use Guides