Choosing the most suitable Deviflex™ cable
Use the tables below to help you plan your Electric Heating System. It is important to establish which cable type your installation requires; considering the desired heat output, the floor construction and the size of the area to be heated.
STEP ONE:
Establish the amount of heat required to heat the area (also called the heat load).
STEP TWO:
Evaluate the floor construction. Then, based on the load required, the floor construction and the maximum load that the different cable types emit, select the most suitable Deviflex™ electric heating cable system.
STEP 3:
Using the size of the area to be heated and the cable type, calculate the required cable spacing using either the Cable Length or the Area Loading:
(see the floor heating installation instructions)
Typical Area Loadings W/m2
| 24 Hour Extended Off-Peak Tariffs Max. Slab Temp = 50ºC |
Off-Peak Systems Max. 14 Hours out of 24 |
Screeds |
Snow melting Off-Peak 24 Hour Tariff |
50 - 180
(200 max.) |
105 - 200
(250 max.) |
50 - 80
(200 max.) |
180 - 250
(300 max.) |
Maximum Load on Heating Cables W/m (20ºC)
| Cable Type |
In Concrete |
In Screed
(min 25 mm) on Concrete |
In Screed
on Membranes |
In Screed
on Timber Floors, Insulation or Under Timber Floors |
DSOT
DSIG |
34
19 |
N/A
19 |
N/A
15 |
N/A
10 |