DEVI self-limiting cables have been developed for refrigeration applications, trace heating, pipe, gutter and doorframe installations. They can be attached to pipes, installed in sand/cement screed beds, around doorways, in gutters etc for a number of different electric heating applications.
Delivery Times to be confirmed - LIMITED STOCK HELD
DEVI pipeheat
DPH-10
Blue
Construction:
Tinned copper bus wires (cross section 0.56m2)
Self-limiting parallel heating element
Polyolefin insulation jacket
Tinned copper braiding 2.44m2
Fluropolymer over jacket
Typical Use: Frost Protection of the inside and outside of water pipes
Technical Reference
Voltage
240V~
Rated Output
10W/m at 10ºC
Dimensions
7.3mm x 5.3mm
Minimum Bending Radius
35mm (internal radius)
Minimum Use Temperature
-30ºC
Maximum Operating Temperature
+65ºC(when powered)
Maximum Installation Length
(max 10 Amp)
100m
Devi-flexheat
DFH-15
Green
Construction:
Tinned copper bus wires (cross section 0.56m2)
Self-limiting parallel heating element
Polyolefin insulation jacket
Tinned copper braiding 2.44m2
Fluropolymer over jacket
Typical Use: Floor Heating
Technical Reference
Voltage
240V~
Rated Output
15W/m at 25ºC
Dimensions
7.3mm x 5.3mm
Minimum Bending Radius
35mm (internal radius)
Minimum Use Temperature
-30ºC
Maximum Operating Temperature
+65ºC (when powered)
Maximum Installation Length
(max 10 Amp)
100m
Devi-iceguard 18
Black
Construction:
Tinned copper bus wires (cross section 1.25m2)
Self-limiting parallel heating element
Double polyolefin insulation jacket
Tinned copper braid shield
Outer polyolefin insulation
Typical Use: Frost Protection of roof gutters and downpipes
Technical Reference
Voltage
240V~
Rated Output
18W/m at 0ºC
Dimensions
11.5mm x 5.5mm
Minimum Bending Radius
25mm (internal radius)
Minimum Use Temperature
-30ºC
Maximum Operating Temperature
+65ºC (when powered)
+85ºC (when un- powered)
Maximum Installation Length
(max 10 Amp)
100m
Devi-pipeguard 26
Red
Construction:
Tinned copper bus wires (cross section 1.25m2)
Self-limiting parallel heating element
Double polyolefin insulation jacket
Tinned copper braid shield
Outer polyolefin insulation
Typical Use: Prevention of freezing liquid in pipes and drain lines as well as the prevention of ice build-up around refrigerated doors/cabinets
Technical Reference
Voltage
240V~
Rated Output
26W/m at 10ºC
Dimensions
11.5mm x 5.5mm
Minimum Bending Radius
25mm (internal radius)
Minimum Use Temperature
-30ºC
Maximum Operating Temperature
+65ºC (when powered)
+85ºC (when un- powered)
Maximum Installation Length
(max 10 Amp)
100m
Devi-hotwatt 55
Red
Construction:
Tinned copper bus wires (cross section 1.25m2)
Self-limiting parallel heating element
Double polyolefin insulation jacket
Tinned copper braid screen
Typical Use: Maintains hot water temperature at approximately +55ºC and is also used to prevent liquids solidifying around tanks, pipe runs etc.